Model |
SJ-E036L |
SJ-E060L |
SJ-E084L |
SJ-E108L |
SJ-E132L |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method/ |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V *1 |
|||||||
Operating distance |
50 to 2000 mm |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm |
||||||||
Alarm output |
||||||||
Communication feature |
Remote control communication |
|||||||
Major features |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
|||||||
Effective length |
440 mm *3 |
680 mm *3 |
920 mm *3 |
1160 mm *3 |
1400 mm *3 |
|||
Total length |
350 mm |
560 mm |
800 mm |
1040 mm |
1280 mm |
|||
No. of electrodes |
5 |
9 |
13 |
17 |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
||||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
670 g |
850 g |
1070 g |
1270 g |
1500 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E156L |
SJ-E180L |
SJ-E204L |
SJ-E228L |
SJ-E252L |
SJ-E300L |
|||
Image |
|
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
||||||||
Structure |
Shockless resistive coupling type |
||||||||
Voltage application method/ |
Pulse AC method/±8000 V |
||||||||
Ion balance control method |
Hi-Power I.C.C. method |
||||||||
Ion balance |
±30 V *1 |
||||||||
Operating distance |
50 to 2000 mm |
||||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
|||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
|||||||
Condition alarm |
|||||||||
Alarm output |
|||||||||
Communication feature |
Remote control communication |
||||||||
Major features |
Condition alarm, ion level alarm, alarm output |
||||||||
Air connection port |
Rc 1/8 |
||||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
||||||||
Effective length |
1640 mm *3 |
1880 mm *3 |
2120 mm *3 |
2360 mm *3 |
2600 mm *3 |
3080 mm *3 |
|||
Total length |
1520 mm |
1760 mm |
2000 mm |
2240 mm |
2480 mm |
2960 mm |
|||
No. of electrodes |
25 |
29 |
33 |
37 |
41 |
49 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
|||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
||||||||
Overvoltage category |
I |
||||||||
Pollution degree |
2 |
||||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
|||||||
Relative humidity |
35 to 85% RH (no condensation) |
||||||||
Material |
Electrode probe |
Tungsten |
|||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
||||||||
Weight |
1700 g |
1900 g |
2100 g |
2300 g |
2500 g |
2900 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E036H |
|||
Image |
|
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/ |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm |
||||
Alarm output |
||||
Communication feature |
Remote control communication |
|||
Major features |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
|||
Effective length |
420 mm *3 |
|||
Total length |
350 mm |
|||
No. of electrodes |
9 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
680 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E036A |
SJ-E060A |
SJ-E084A |
SJ-E108A |
SJ-E132A |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method/ |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V *1 |
|||||||
Operating distance |
50 to 2000 mm |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm |
||||||||
Alarm output |
||||||||
Major features |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
|||||||
Effective length |
420 mm *3 |
660 mm *3 |
900 mm *3 |
1140 mm *3 |
1380 mm *3 |
|||
Total length |
350 mm |
560 mm |
800 mm |
1040 mm |
1280 mm |
|||
No. of electrodes |
5 |
9 |
13 |
17 |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
||||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
670 g |
850 g |
1070 g |
1270 g |
1500 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E156A |
SJ-E180A |
SJ-E204A |
SJ-E228A |
SJ-E252A |
SJ-E300A |
|||
Image |
|
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
||||||||
Structure |
Shockless resistive coupling type |
||||||||
Voltage application method/ |
Pulse AC method/±8000 V |
||||||||
Ion balance control method |
Hi-Power I.C.C. method |
||||||||
Ion balance |
±30 V *1 |
||||||||
Operating distance |
50 to 2000 mm |
||||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
|||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
|||||||
Condition alarm |
|||||||||
Alarm output |
|||||||||
Major features |
Condition alarm, ion level alarm, alarm output |
||||||||
Air connection port |
Rc 1/8 |
||||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
||||||||
Effective length |
1620 mm *3 |
1860 mm *3 |
2100 mm *3 |
2340 mm *3 |
2580 mm *3 |
3060 mm *3 |
|||
Total length |
1520 mm |
1760 mm |
2000 mm |
2240 mm |
2480 mm |
2960 mm |
|||
No. of electrodes |
25 |
29 |
33 |
37 |
41 |
49 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
|||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
||||||||
Overvoltage category |
I |
||||||||
Pollution degree |
2 |
||||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
|||||||
Relative humidity |
35 to 85% RH (no condensation) |
||||||||
Material |
Electrode probe |
Tungsten |
|||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
||||||||
Weight |
1700 g |
1900 g |
2100 g |
2300 g |
2500 g |
2900 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E036N |
|||
Image |
|
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistor connection type |
|||
Voltage application method/ |
Pulse AC method/±8,000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V |
|||
Operating distance |
50 to 2,000 mm |
|||
Communication feature |
RS-485 communication/remote control communication |
|||
Major features |
Condition alarm, ion level alarm, and alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1 |
|||
Effective length |
440 mm*2 |
|||
Total length |
350 mm |
|||
No. of electrodes |
5 |
|||
Rating |
Power voltage |
24 to 36 VDC ±10 % |
||
Current consumption |
700 mA (at 24 V) or 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
670 g |
|||
*1 Contact us for details on this value when the air supply is opened and closed. |