Separate Amplifier Proximity Sensor
ES series
Specs Separate Amplifier Proximity Sensor ES series
Model |
EH-302 |
EH-303A |
EH-305 |
EH-308 |
EH-110 |
EH-114 |
|||
Image |
|
|
|
|
|
|
|||
Type |
Standard, Shielded , Cylindrical |
Standard, Shielded ,Threaded |
|||||||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
||||||||
Standard target (iron, t=1 mm) |
5 x 5 mm |
10 x 10 mm |
15 x 15 mm |
||||||
Stable detecting range |
0 to 0.6 mm |
0 to 0.8 mm |
0 to 1 mm |
0 to 2 mm |
0 to 5 mm |
||||
Maximum detecting distance |
1.2 mm |
2 mm |
3 mm |
5 mm |
8 mm |
||||
Hysteresis |
0.04 mm |
0.05 mm |
0.04 mm |
0.05 mm |
|||||
Repeatability |
0.002 mm |
0.005 mm |
|||||||
Temperature characteristics |
±10% max. of detecting distance at +23°C, within -10 to +60°C |
||||||||
Environmental resistance |
Enclosure rating |
IP67 |
|||||||
Ambient temperature |
-10 to +60 °C (No freezing) |
||||||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||||
Weight |
Approx. 29 g (including 3-m cable) |
Approx. 38 g (including 3-m cable) |
Approx. 45 g (including 3-m cable) |
Approx. 47 g (including 3-m cable) |
Approx. 55 g (including nuts and 3-m cable) |
Approx. 62 g (including nuts and 3-m cable) |
Model |
EH-605 |
EH-614A |
EH-108 |
EH-910 |
|||
Image |
|
|
|
|
|||
Type |
Standard , Shielded , ULTRA thin |
Oil-resistant, Shielded, Threaded*1 |
Solvent resistant , Shielded , Cylindrical |
||||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
||||||
Standard target (iron, t=1 mm) |
5 x 5 mm |
15 x 15 mm |
10 x 10 mm |
||||
Stable detecting range |
0 to 1 mm |
0 to 5 mm |
0 to 1.5 mm |
0 to 2 mm |
|||
Maximum detecting distance |
3 mm |
8 mm |
2.5 mm |
4.5 mm |
|||
Hysteresis |
0.05 mm |
0.07 mm |
0.06 mm |
||||
Repeatability |
0.002 mm |
0.005 mm |
|||||
Temperature characteristics |
-10 to+20% max. of detecting distance at 23°C, within -10 to +60°C |
±10% max. of detecting distance at +23°C, within -10 to +60°C |
-10 to+15% max. of detecting distance at 23°C, within 0 to 60°C |
||||
Environmental resistance |
Enclosure rating |
IP67 |
|||||
Ambient temperature |
-10 to +60 °C (No freezing) |
||||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Weight |
Approx. 30 g (including nuts and 3-m cable) |
Approx. 57 g (including nuts and 3-m cable) |
Approx. 51 g (including nuts and 3-m cable) |
Approx. 53 g (including nuts and 3-m cable) |
|||
*1 Not designed for immersed use. |
Model |
EH-305S |
EH-308S |
EH-110S |
|||
Image |
|
|
|
|||
Type |
with stainless steel spiral tube, Shielded , Cylindrical |
with stainless steel spiral tube , Shielded , Threaded |
||||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||||
Standard target (iron, t=1 mm) |
5 x 5 mm |
10 x 10 mm |
||||
Stable detecting range |
0 to 1 mm |
0 to 2 mm |
||||
Maximum detecting distance |
3 mm |
5 mm |
||||
Hysteresis |
0.05 mm |
0.04 mm |
||||
Repeatability |
0.002 mm |
0.005 mm |
||||
Temperature characteristics |
±10% max. of detecting distance at +23°C, within -10 to +60°C |
|||||
Environmental resistance |
Enclosure rating |
IP67 |
||||
Ambient temperature |
-10 to +60 °C (No freezing) |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||
Weight |
Approx. 76 g (including 3-m cable) |
Approx. 88 g (including 3-m cable) |
Approx. 100 g (including nuts and 3-m cable) |
Model |
EH-402 |
EH-416 |
EH-422 |
EH-430 |
EH-440 |
EH-290 |
|||
Image |
|
|
|
|
|
|
|||
Type |
Standard , Non-shielded , Cylindrical |
Standard , Non-shielded , Cylindrical and threaded |
Standard , Non-shielded , Cylindrical |
||||||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
||||||||
Standard target (iron, t=1 mm) |
10 x 10 mm |
20 x 20 mm |
25 x 25 mm |
30 x 30 mm |
40 x 40 mm |
150 x 150 mm |
|||
Stable detecting range |
0 to 3 mm |
0 to 6 mm |
0 to 9 mm |
0 to 12 mm |
0 to 18 mm |
0 to 35 mm |
|||
Maximum detecting distance |
7 mm |
13 mm |
18 mm |
25 mm |
36 mm |
70 mm |
|||
Hysteresis |
0.04 mm |
0.05 mm |
0.06 mm |
0.08 mm |
0.1 mm |
0.2 mm |
|||
Repeatability |
0.002 mm |
0.012 mm |
0.02 mm |
0.025 mm |
0.037 mm |
0.075 mm |
|||
Temperature characteristics |
+30%, -10% max. of detecting distance at +23°C, within -10 to +60°C |
±10% max. of detecting distance at +23°C, within -10 to +60°C |
|||||||
Environmental resistance |
Enclosure rating |
IP67 |
|||||||
Ambient temperature |
-10 to +60 °C (No freezing) |
||||||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||||
Weight |
Approx. 28 g (including nuts and 3-m cable) |
Approx. 72 g (including nuts and 3-m cable) |
Approx. 175 g (including nuts and 3-m cable) |
Approx. 225 g (including nuts and 3-m cable) |
Approx. 280 g (including nuts and 3-m cable) |
Approx. 650 g (including nuts and 3-m cable) |
Model |
ES-M1*1 |
ES-M2*1 |
ES-M1P*1 |
ES-M2P*1 |
|||
Image |
|
|
|
|
|||
Type |
One-line expansion system |
||||||
Shape |
Main unit |
Expansionunit |
Main unit |
Expansionunit |
|||
Operation mode |
N.O./N.C. (switch-selectable) |
||||||
Timer function |
10-ms delay / timer OFF switchable*2 |
||||||
Output |
NPN |
PNP |
|||||
Output |
Control output |
NPN open collector 100 mA max. |
PNP open collector 100 mA max. |
||||
Disconnection alarm output |
NPN open |
―*3 |
PNP open |
―*3 |
|||
Response time |
1 ms max. |
||||||
Temperature characteristics |
Within ±8% of detecting distance at 23°C |
||||||
Sensitivity adjustment |
25-turn trimmer |
||||||
Protection circuit |
Reverse power connection protection, output |
||||||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
|||||
Current/power consumption |
25 mA max. |
||||||
Environmental resistance |
Ambient temperature |
0 to +50 °C*4 |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Weight |
Approx. 65 g (including nuts and 2-m cable) |
Approx. 35 g (including nuts and 2-m cable) |
Approx. 65 g (including nuts and 2-m cable) |
Approx. 35 g (including nuts and 2-m cable) |
|||
*1 The ES-M1(P)/M2(P) cannot be connected to the EH-422, 430, 440 or 290. |
Model |
ES-32DC |
|||
Image |
|
|||
Type |
DC |
|||
Operation mode |
N.O./N.C. (switch-selectable) |
|||
Indicator |
Output: Red LED |
|||
Output |
Control output |
NPN: 200 mA (40 V) max. |
||
Disconnection alarm output |
NPN: 100 mA (40 V) max. |
|||
Leakage current (OFF time) |
― |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
±8% of detecting distance at 23°C within 0 to 50°C |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Rating |
Power voltage |
10 to 28 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
18 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 48 g |