High Power Digital Ultrasonic Sensors
FW series
Amplifier Unit FW-V25
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | FW-V25 | |||
Type | NPN | |||
Rating | Power voltage | 24 VDC, Ripple (P-P): 10% max. | ||
Current consumption | When connected with the FW-H02/H07 | Normal | 1680 mW (70 mA) or less*1 | |
Power save | 1370 mW (57 mA) or less*1 | |||
When connected with the FW-H10R | Normal | 2640 mW (110 mA) or less*1 | ||
Power save | 2330 mW (97 mA) or less*1 | |||
Display power | 2-row display with signed 3-digit, 7-segment LED (Character height: Upper row: 8 mm, red; Lower row: 5.7 mm, green) | |||
Operation status indicators | Red LED x 2 (corresponding to Control output 1 and Control output 2), Green LED x 2 (Display CH indicator) | |||
Chattering prevention function | Selectable from OFF, 0.5, 1, 2, 5, and 10s (Selectable from OFF, 1, 2, 5, and 10s when connected to the FW-H10R) | |||
Bank/external shift input | Non-voltage input (contact/non-contact inputs), Input time: 25 ms min. (This input/analogue output is selectable.) | |||
Controloutput | NPN open collector, 100 mA 40 V max. | |||
Protection circuit | Reverse connection protection, over-current protection, surge absorber | |||
Analogue output | 4 to 20 mA, maximum load resistance: 260 Ω (Bank/external shift input/analog output selectable) | |||
Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing) | ||
Relative humidity | 35 to 85 % RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | |||
Material | Main unit and cover: Polycarbonate, Keycaps: elastomer | |||
Accessories | Panel mounting bracket, Protective front cover, Power cable, Instruction manual | |||
Weight | Approx. 85 g (Including a 2-m power cable) | |||
*1 Excluding analog output. Includes head unit. |