Digital Fibre Optic Sensors

FS-N series

Catalogues View Catalogue

Fibre Amplifier, M8 Connector Type, Expansion Unit, PNP FS-N14CP

FS-N14CP - Fibre Amplifier, M8 Connector Type, Expansion Unit, PNP

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

FS-N14CP

Type

High functionality 2 output
M8 connector*1

Output

PNP

Main unit/Expansion unit

Expansion unit

Control output

2
PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

External input

-

Light source

Red, 4-element LED

APC

ON/OFF switchable (Factory setting: OFF)

Response time

50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

Number of interference prevention units

0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)

Unit expansion

Up to 16 units can be connected total (two output type is treated as two units)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current Consumption

Normal: 1050 mW or less (42 mA max. at 24 V, 56 mA max. at 12 V)*2
Eco on mode: 950 mW or less (38 mA max. at 24 V, 47 mA max. at 12 V)*2
Eco Full mode: 600 mW or less (24 mA max. at 24 V, 29 mA max. at 12 V)

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less

Ambient temperature

-20 to +55 °C (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Both main unit and expansion unit housing material: Polycarbonate

Weight

Approx. 22 g

*1 Use a cable length of 30 m or less for M8 connector types.
*2 Increases 100 mW (4.0 mA) for High Speed mode
*3 One or two more units connected: -20 to +55 °C; 3 to 10 more units connected: -20 to +50 °C; 11 to 16 more units connected: -20 to +45 °C. When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.