Heavy Duty Type Digital Pressure Sensors
GP-M series
Specs Heavy Duty Type Digital Pressure Sensors GP-M series
Model |
GP-M001 |
GP-M010 |
GP-M025 |
GP-M100 |
GP-M250 |
GP-M400 |
|||
Image |
|
|
|
|
|
|
|||
Rated pressure |
-100 to +100 kPa |
-0.1 to +1 MPa |
-0.1 to +2.5 MPa |
0 to +10 MPa |
0 to +25 MPa |
0 to +40 MPa |
|||
Possible display range |
-120.0 to +120.0 kPa |
-0.210 to +1.110 MPa |
-0.360 to +2.760 MPa |
-1.00 to +11.00 MPa |
-2.50 to +27.50 MPa |
-4.00 to +44.00 MPa |
|||
Zero-cut pressure value |
±0.5% of F.S. |
||||||||
Burst pressure |
1.5 MPa (15 bar) |
15 MPa (150 bar) |
35 MPa (350 bar) |
100 MPa (1000 bar) |
|||||
Display resolution |
0.1 kPa (0.001 bar) |
0.001 MPa (0.01 bar) |
0.01 MPa (0.1 bar) |
||||||
Fluid type |
Gas or liquid that will not corrode the liquid contact part |
Liquid that will not corrode the liquid contact part |
|||||||
Type of pressure |
Gage pressure |
||||||||
Precision |
±1.0% of F.S. or less*1 |
||||||||
Repeatability |
±0.3% of F.S. or less*2 |
||||||||
Temperature characteristics |
±0.6% of F.S./10°C |
||||||||
Connection diameter |
G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) |
||||||||
Box rotation angle |
Maximum 330° |
||||||||
Medium temperature |
-20 to +100°C (no freezing/condensation)*3 |
||||||||
Power supply voltage |
10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS |
||||||||
Current consumption |
50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4 |
||||||||
Display method |
4 column, digital LED, red/Vertical inversion display possible |
||||||||
Operation display light |
Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) |
||||||||
Hysteresis |
During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) |
||||||||
Response |
Control output |
Selectable from 3 to 5000 ms |
|||||||
Analogue output |
As above + 2 ms (90% response) |
||||||||
Output |
Output 1 control output |
NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) |
|||||||
Output 2 |
Control output |
||||||||
Analogue output |
4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5 |
||||||||
Environmental resistance |
Enclosure rating |
IP67 |
|||||||
Pressure resistance |
400 kPa (4 bar) |
4 MPa (40 bar) |
10 MPa (100 bar) |
30 MPa (300 bar) |
50 MPa (500 bar) |
||||
Ambient temperature |
-20 to +80 °C (No freezing and no condensation) |
||||||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||||
Vibration resistance |
IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes) |
||||||||
Shock resistance |
IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) |
||||||||
Material |
Port/diaphragm |
Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM |
|||||||
Other parts |
Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass. |
Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU |
|||||||
Applicable cable |
M12 connector 4 pin |
||||||||
Weight |
Approx. 150 g |
||||||||
*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C. |