Model

GP-M001

GP-M010

GP-M025

GP-M100

GP-M250

GP-M400

Image

Rated pressure

-100 to +100 kPa
(-1 to +1 bar)

-0.1 to +1 MPa
(-1 to +10 bar)

-0.1 to +2.5 MPa
(-1 to +25 bar)

0 to +10 MPa
(0 to +100 bar)

0 to +25 MPa
(0 to +250 bar)

0 to +40 MPa
(0 to +400 bar)

Possible display range

-120.0 to +120.0 kPa
(-1.200 to +1.200 bar)

-0.210 to +1.110 MPa
(-2.10 to +11.10 bar)

-0.360 to +2.760 MPa
(-3.60 to +27.60 bar)

-1.00 to +11.00 MPa
(-10.0 to +110.0 bar)

-2.50 to +27.50 MPa
(-25.0 to +275.0 bar)

-4.00 to +44.00 MPa
(-40.0 to +440.0 bar)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

1.5 MPa (15 bar)

15 MPa (150 bar)

35 MPa (350 bar)

100 MPa (1000 bar)

Display resolution

0.1 kPa (0.001 bar)

0.001 MPa (0.01 bar)

0.01 MPa (0.1 bar)

Fluid type

Gas or liquid that will not corrode the liquid contact part

Liquid that will not corrode the liquid contact part

Type of pressure

Gage pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S./10°C

Connection diameter

G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle

Maximum 330°

Medium temperature

-20 to +100°C (no freezing/condensation)*3

Power supply voltage

10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption

50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display method

4 column, digital LED, red/Vertical inversion display possible

Operation display light

Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)

Hysteresis

During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)

Response

Control output

Selectable from 3 to 5000 ms

Analogue output

As above + 2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable

Output 2
replacement type

Control output

Analogue output

4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5

Environmental resistance

Enclosure rating

IP67

Pressure resistance

400 kPa (4 bar)

4 MPa (40 bar)

10 MPa (100 bar)

30 MPa (300 bar)

50 MPa (500 bar)

Ambient temperature

-20 to +80 °C (No freezing and no condensation)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes)

Shock resistance

IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction)

Material
properties

Port/diaphragm

Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM

Other parts

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g

*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C.
*2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition.
*3 When the temperature of the piping exceeds 80°C, do not connect the cable.
*4 Consumption current including output is 0.6 A and under.
*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω

Back to top