Ethernet Switch
NE series
Specs Ethernet Switch NE series
Model |
NE-Q05 |
NE-Q05P |
|||
Image |
|
|
|||
General specifications |
Current consumption |
180 mA |
2.2 A |
||
Power voltage |
24 VDC ±10% |
||||
Operating ambient temperature |
0 to +50°C*1 (no freezing) |
||||
Operating ambient humidity |
10 to 95%RH (no condensation) |
||||
Ambient temperature for storage |
-20 to +70°C |
||||
Operating environment |
Without dust and corrosive gas |
||||
Altitude |
2000m or less |
||||
Noise immunity |
1500 Vp-p Pulse width 1 µs, 50 ns |
||||
Withstand voltage |
1,500 VAC for 1 minute (between the power supply terminal and the I/O terminals and between all the external terminals and the case) |
||||
Insulation resistance |
50 MΩ and above (measured between power terminals |
||||
Shock resistance |
Acceleration 150 m/s2, Operation time 11 ms, twice in each |
||||
Overvoltage category |
I |
||||
Pollution degree |
2 |
||||
Vibration resistance |
Intermittent vibration |
Frequency: 10 to 57 Hz |
Amplitude: 0.075 mm*2 |
||
Frequency: 57 to 150 Hz |
Acceleration: 9.8 m/s2*2 |
||||
Continuous vibration |
Frequency: 10 to 57 Hz |
Amplitude: 0.035 mm*2 |
|||
Frequency: 57 to 150 Hz |
Acceleration: 4.9 m/s2*2 |
||||
Weight |
Approx 180g |
Approx 260g |
|||
Function/performance specifications |
Data transfer speed |
10 Mbps, 100 Mbps, automatic support for full duplex and half duplex modes |
|||
MDI/MDI-X automatic switching function |
Provided |
||||
Auto-negotiation function |
|||||
Communicationspecifications |
MAC address retention |
300 s |
|||
Function/performance specifications |
Upper limit for the number of MAC addresses that can be registered |
2048 |
|||
QoS function |
Priority control of EtherNet/IP™ cyclic data |
||||
PoE function |
None |
2 ports, conforms to IEEE802.3af, supply power: 15.4 W/port (44 to 57 VDC) |
|||
Communicationspecifications |
Switching type |
Store and forward method |
|||
Metal cable |
Flow control |
Half duplex: back pressure, full duplex: conforms to IEEE802.3x; pose packets are used to perform flow control |
|||
*1 This is regulated according to the temperature below the control panel unit. |