Single-phase 100 to 115 VAC (for 400 W) SV-040L1

SV-040L1 - Single-phase 100 to 115 VAC (for 400 W)

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

SV-040L1

Power supply/current capacity and power loss

Maximum applicable motor capacity Single-phase 100 VAC

400 W

Power capacity (VA) per amplifier Single-phase 100 VAC

1400 VA

Output current Continuous

Single-phase 100 VAC

2.8 Arms

Output current Maximum

9.3 Arms

Main circuit power loss Single-phase 100 VAC

25.6 W

Control circuit power loss Single-phase 100 VAC

17 W

Total power loss Single-phase 100 VAC

42.6 W

Input rated current

Main circuit Single-phase 100 VAC

10 Arms

Control circuit Single-phase 100 VAC

0.38 Arms

Rush current

Main circuit Single-phase 100 VAC

16.5 A*1

Control circuit Single-phase 100 VAC

35 A*1

General specifications

Type

For 100 V

Capacity

400W

Input power supply

Voltage/frequency

Main circuit

Single phase 100 to 115 VAC, 50/60 Hz

Control circuit

Main circuit/control circuit

Allowable voltage fluctuation

85 to 127 VAC

Allowable frequency fluctuation

±5% or less

Allowable instantaneous outage time

Main circuit

Full (100% down): 0.5 cycle, Partial (50% down): 1 cycle

Control circuit

Approx 65ms

Overvoltage category

III

Control method

3-phase full-wave rectification, IGBT PWM control, sinusoidal current drive system

Feedback

Operating environment

Operating ambient temperature

0 to +55°C (no freezing)

Ambient storage temperature

-20 to +70°C (no freezing)

Ambient operating/storage humidity

90%RH or less (no condensation)

Vibration resistance

4.9 m/s2 (conforms to JIS C 60068-2-6)

Shock resistance

19.6 m/s2 (conforms to JIS C 60068-2-27)

Operating atmosphere (enclosure rating/pollution degree)

Pollution degree: 2 (within a control panel that has a rating of IP54 or higher), however, · No corrosive or flammable gas present · A location that is not subject to water, oil, or drugs · No dust present

Altitude

1,000 m or less above sea level

Approved standards

UL/CSA standards

UL508C, and CSA C22.2 No.14

CE marking

Low-voltage directive

EN50178

EMI

EN55011 Class A, EN61800-3

EMS

EN61800-3, EN61000-6-2

North American EMI standards

FCC Part15 B, ICES-003. Class A

Structure

Type

Base mounting attachment

Protection

Open, forced

Lowest insulation resistance value

1 MΩ or more, tested with a 500 VDC megger

Insulation withstand voltage

1,500 VAC or more (between the primary side and the earth terminal), 1,800 VAC or more (between the primary side and the secondary side)

Weight

Approx 1.5kg

Performance specifications

Performance

Speed control range

1 to 5,000 (under the condition that the load torque is less than or equal to the rated torque)

Speed fluctuation rate

During load fluctuation

±0.01% or less with a load fluctuation between 0 and 100% (at the rated rotation speed)

When the voltage of the main circuit fluctuates

0% at the rated voltage ±10% (at the rated rotation speed)

When the ambient temperature fluctuates

±0.1% or less when the ambient temperature is between 0 and +50°C (at the rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Speed frequency response

1.6 kHz (when JL = JM) * JL: load moment of inertia (motor axis conversion), JM: motor moment of inertia

Dynamic brake

Built-in

Analogue monitor output for observation

Monitor output such as motor rotation speed and torque instruction for observations, number of built-in channels: 2

Regenerative resistor

Built-in regenerative resistor

None

External regenerative resistor

OP-84399 (220 W*2)

Display function

Access window

Status monitor, parameter settings, calibration, etc.

CHARGE display LED

CHARGE LED (orange) for checking the main circuit power supply input

Status

Servo on, instruction input in progress, warning, MECHATROLINK-II communication in progress

Communication function

USB communication

Function

Status display, parameter settings, calibration, etc.

Connection device

PC

Protection function

Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, etc.

Other functions

Auto calibration, absolute position system, etc.

I/O specifications

MECHATROLINK-II type

Control I/O

Input signal: Number of channels

8CH

Input signal: Function

Forced stop (FSTOP), forward rotation side limit switch (LSP), reverse rotation side limit switch (LSN), external latch signals 1 to 3 (EXT1, EXT2, EXT3), forward rotation side torque limit selection (PTL), reverse rotation side torque limit selection (NT

Output signal: Number of channels

4CH

Output signal: Function

Alarm (ALARM), operation preparation complete (RDY), in position (INPOS), speed matching (VCMP), electromagnetic brake timing (BRAKE), torque control in progress (TLM), speed control in progress (VLM), warning (WARN), zero-speed detection (ZSP), near posi

Encoder division pulse output

A-phase (A+, A-), B-phase (B+, B-), Z-phase (Z+, Z-): line-driver output;*3 Z-phase (ZOC): open-collector output; number of division pulses: 1.6 Mpps maximum (6.4 MHz when 2-phase 4× selected)*4

Communication specifications (MECHATROLINK-II type only)

MECHATROLINK communication

Station address

41 H to 5 FH (up to 30 slave stations connected)
(The first digit is selected with access window, and the second digit is selected with the rotary switch.)

Transmission speed

MECHATROLINK-II

10 Mbps (selected with access window)

MECHATROLINK-I

4 Mbps (selected with access window)

Transmission frequency

MECHATROLINK-II

250 µs, 0.5 to 4.0 ms (multiples of 0.5)

MECHATROLINK-I

2ms

Transmission byte number

MECHATROLINK-II

17 bytes/station, 32 bytes/station (selected with access window)

MECHATROLINK-I

17 bytes/station

Command method

Operation specifications

Position control, speed control, and torque control performed by way of MECHATROLINK communication

Command input

MECHATROLINK-II Command (sequence control Programme/motion/data setting/reference/monitoring/adjustment etc)

I/O terminal specifications and wiring

General-purpose input (DI-1)

Maximum input voltage

26.4 VDC

Input rated voltage

24 VDC (5mA)

Minimum ON voltage

19 VDC

Maximum OFF current

0.1mA

Common ground

Common (MECHATROLINK-II type servo amplifiers only have positive commons.)

General-purpose output (DO-1)

Output

Open-collector output

Rated load

30 VDC (30mA)

Leakage current (at OFF)

0.1mA

Residual voltage (at ON)

1.6 VDC or less

Common ground

Common

2-wire method compatible input (DI-2)

Maximum input voltage

26.4 VDC

Input rated voltage

24 VDC (9mA)

Minimum ON voltage

19 VDC

Maximum OFF current

1.5mA

Common ground

Common (MECHATROLINK-II type servo amplifiers only have positive commons.)

2-wire method compatible high-speed input (DI-3)

Maximum input voltage

26.4 VDC

Input rated voltage

24 VDC (11mA)

Minimum ON voltage

19 VDC

Maximum OFF current

1.5mA

Common ground

Common

Z phase open-collector output (DO-2)

Output

Non-isolated open-collector output

Rated load

30 VDC (30mA)

Leakage current (at OFF)

0.1mA

Residual voltage (at ON)

1.2 VDC or less

Common ground

Non-isolated

Output frequency

50kHz

Encoder output (DO-E)

Output

Differential line-driver output

Output voltage

Corresponds to AM26C31

Common ground

Independent (non-isolated)

Output frequency

Phase difference: 1.6 Mpps (after 4×: 6.4 MHz)

*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower.
*2 The rated capacity is the value with an ambient temperature of 70°C. However, when natural air cooling is being used, use this product with a capacity that is 20% or less of the value written above.
*3 Corresponds to AM26C31
*4 The parameters can be us

Data Sheet (PDF) Other Models